问题描述:客户同时采购AR1200-S 路路由器器和S5724TP-SI 交换机组建公司⼩小型园区⽹网络,⾸首次使⽤用SecureCRT 终
端⼯工具通过串串⼝口线本地登陆对设备进⾏行行配置,SecureCRT 默认配置,登陆AR1200-S 路路由器器⼀一切正常,
同样的串串⼝口线、PC 和终端⼯工具登陆S5700 交换机只能输出信息,却完全⽆无法输⼊入命令⾏行行进⾏行行操作。
处理理过程
1、客户最开始使⽤用的是标配AR1200-S 路路由器器的串串⼝口线登陆S5700 交换机,换成S5700 标配的串串⼝口线
后问题重现,同时这条串串⼝口线登陆AR 路路由器器正常,排除串串⼝口线问题;
2、S5700 交换机console ⼝口损坏,重启交换机,重启过程的打印信息输出正常,且交换机启动⼀一切正
常:
BIOS LOADING ...
Copyright (c) 2008-2010 HUAWEI TECH CO., LTD.
(Ver127, Apr 11 2012, 10:27:20)
Press Ctrl+B to enter BOOTROM menu... 0
Auto-booting...
Update Epld file ............................ None
Update FansCard file ........................ None
Decompressing VRP software .................. done
USB2 Host Stack Initialized.
USB Hub Driver Initialized
USBD Wind River Systems, Inc. 512 Initialized
EHCI Controller found.
Waiting to attach to USBD...
USB_MODE_REG=0x3
Done.
usbPegasusEndInit () returned OK
0x62ffe68 (tRootTask): usbBulkDevInit () returned OK
PPI DEV SysInit......OK
Vrrp cmd disable...
BFD cmd disable...Hard system init.................OK
Begin to start the system, please waiting ......
VOS VFS init.....................OK
VOS monitor init.................OK
CFM init advance.................OK
PAT init ........................OK
HA S2M init......................OK
VOS VFS init hind ...............OK
VRP_Root begin...
VRP_InitializeTask begin...
Init the Device Link.............OK
CFG_PlaneInit begin..............OK
CFM_Init begin...................OK
CLI_CmdInit begin................OK
VRP_RegestAllLINKCmd begin.......OK
create task begin................
task init begin...
Recover configuration...OK!
Press ENTER to get started.
排除console ⼝口损坏;
3、检查SecureCRT 登陆配置,客户采⽤用默认配置:
流控选项⾥里里选择了了RTS/CTS,将此流控选项去掉,保证流控为⽆无,之后再次登陆S5700 交换机,恢复
正常,可以正常输⼊入输出,进⾏行行配置等操作。
根因
1、串串⼝口线损坏
2、S5700 交换机console ⼝口损坏
3、SecureCRT 设置错误
建议与总结
采⽤用SecureCRT 终端⼯工具本地登陆AR 路路由器器与S5700 交换机时,流控选项⾥里里,勾选RTS/CTS 时,
登陆AR 路路由器器正常,但是对于S5700 交换机,必须将流控位全部去掉,才能正常登陆交换机。建议
采⽤用SecureCRT 登陆AR 路路由器器和S 系列列盒式交换机时,流控位全部勾掉,可保证都能正常登陆。